NEW TRAFFIC LIGHT CONTROL UNIT

VIACONTROL

Smart traffic-light control, made simple.

Three different operating logics, a clear 2.2" colour display and a 6-module DIN body that fits into any electrical panel.

VOLTAGE 24V – 230V
OUTPUTS 2 traffic lights
ENCLOSURE 6-module DIN
WHAT IT IS

Smart traffic-light control, zero complications.

VIACONTROL is the new Stagnoli traffic light controller for gates, crossings and private roads. A single compact 6-module DIN unit drives two traffic lights, with auxiliary outputs ready for the rest of your automation.

Where traditional controllers force you to think in terms of wiring, VIACONTROL thinks in states. Connect the traffic lights, choose a mode, set two timers. Done.

viacontrol din rail installation icon

Easy installation in any electrical panel

The compact 6-module DIN enclosure clips onto a standard rail. No external board, no custom bracket.

Viacontrol Universal Voltage 24v 230v Icon

Universal voltage: 24V – 230V

One unit, both power supplies. The same VIACONTROL accepts a 24V or 230V input: choose the wiring best suited to the panel and install it.

viacontrol fast programming icon

Intuitive, fast programming

A 2.2" colour display and a four-button menu guide you through configuration in just a few minutes: no PC, no app, no cables.

viacontrol control logic timing icon

Reliable control logic

Three operating logics that are simple to set up. No conflicts, no surprises after a power cycle.

viacontrol aux outputs icon

AUX outputs ready for automation

Two configurable auxiliary contacts drive gate motors, barriers, alarms or signage without an additional relay board.

viacontrol two traffic lights icon

Two traffic lights, one single unit

A single VIACONTROL drives a complete pair of two- or three-colour signal heads.

Close-up of the VIACONTROL display with S1 and S2 status rings, In1 / Aux1 and In2 / Aux2 indicators, and the + / − navigation keys.

Display and interface

Everything that matters, on a single screen.

  • Real-time traffic light status

    See both signal heads in real time, with their active phase.

  • Inputs and AUX at a glance

    Every sensor, button and auxiliary output, visible instantly.

  • Four-button configuration

    + / − / ESC / ENTER. No PC, no app, no extra cable.

Operating modes

Three modes. One single controller.

Choose the right behaviour for the site: sensor-triggered, timed, or manually held.

01

MODE 01

traffic light priority mode icon

Reservation

The cycle starts on demand, when a sensor or a button triggers it.

Activation

External detection

Ideal for

Residential complex exits

02

MODE 02

traffic light timed mode icon

Timing

Alternates the two signal heads on a fixed time, with no sensors required.

Activation

Timed, cyclic

Ideal for

Industrial driveways

03

MODE 03

traffic light state mode icon

State

The green stays on as long as its input is held active.

Activation

Manual / held input

Ideal for

Emergencies, oversized loads

Technical specifications

Dimensions and specifications

VIACONTROL dimensions: 106 × 90.2 mm front · 57.8 mm depth · 42.2 mm window.

Enclosure

6-module DIN

Power supply

24V · 230V (single unit)

Navigation

+ · – · ESC · ENTER

AUX outputs

2 × NC / COM / NO

Accessory power supply

24V · max 0.5 A

Dimensions

106 × 90.2 × 57.8 mm

Display

2.2" colour

Traffic light outputs

2 × R / G / V / COM

Inputs

3 (IN1 / IN2 / IN3)

Operating modes

Reservation · Timing · State

Case Study

One-way access control at a car park entrance.

VIACONTROL in Reservation mode. Two states, one quiet residential exit.

Residential exit on standby — the side road light is red, the main road light is green.

Step 01

Standby

The main road keeps flowing.

Nobody is exiting, so there is no need to interrupt traffic. The unit stays in its default state, waiting for a request.

Main road

Green traffic light

Green

Side road

Red traffic light

Red

Residential exit in cycle — the sensor has detected the resident's car, the side road light is now green and the main road light is red, allowing a safe exit.

Step 02

Exit requested

A safe, timed manoeuvre.

An inductive loop detects a vehicle and activates IN1. The cycle reverses the traffic lights for the preset Green Time, then a Clearance Time keeps the road section safe before returning to standby.

Main road

Red traffic light

Red

Side road

Green traffic light

Green

Specifications, drawings and the complete user manual, all in one place.